Pulsar 710 |
Download Sales Sheet |
- 100 Amps @ 100 Volts total output in strobed mode
- 8 Amps @ 24 Volts total output in constant mode
- Capable of strobing Ai's largest lights
| |
Click to Expand for Specifications |
Pulsar 710 Control Applet |
Signatech software enables the user to program all strobe controller current and timing parameters. Currents are programmable for each of four channels, and expressed in amps from 0-25. Timing parameters include pulse width, and post event delay time. All timing parameters are programmed in steps of 1 microsecond, up to a maximum of 1000. |
| |
Additional Information |
Pulse Parameter |
Range |
Computer Increment |
On Time |
|
|
Delay Time |
|
|
Stop Time |
|
|
Off Time |
|
|
Hold Time |
|
| |
Standard Product Information |
Operating Temperature: |
0-55°C |
Regulatory Compliance |
CE | |
Pulsar 710 Schematic |
| |
DIMENSIONS ARE IN MILLIMETERS (INCHES) | |
|
S4000 |
Download Sales Sheet |
- Features Ai’s proprietary Signatech system
- Provides up to 4 Amps per channel, 4 channels per output
- Provides Ai’s “All color” RGB light heads with independent power level controls for up to four channels within each light head
| |
Click to Expand for Specifications |
S4000 Control Applet |
Signatech Controller Software
Signatech software enables the user to program all strobe controller current and timing parameters. Currents are programmable for each of four channels per output, and expressed in milliamps from 0-4000. Timing parameters include pulse width, pre and post event delay time, trigger repeat setting, and a programmable off-time between repetitions. All timing parameters are programmed in steps of 1 microsecond, up to a maximum of 64000. |
| |
Additional Information |
Pulse Parameter |
Range |
Computer Increment |
On Time |
0 or 1 to 64000 |
1 microsec |
Delay Time |
0 or 10 to 64000 |
1 microsec |
Stop Time |
0 or 1 to 64000 |
1 microsec |
Off Time |
0 or 1 to 64000 |
1 microsec |
Hold Time |
0 or 50 to 64000 |
1 microsec | |
Standard Product Information |
Operating Temperature: |
0-55°C |
Regulatory Compliance |
CE | |
S4000 Schematic |
| |
DIMENSIONS ARE IN MILLIMETERS (INCHES) | |
|
S6000 |
Download Sales Sheet |
- Two independently controlled light head outputs are provided, allowing two cameras to be used in a dual inspection configuration
- Up to 4 Amps per channel, 4 channels per output
- The S6000-AS features asynchronous triggering of outputs
| |
Click to Expand for Specifications |
S6000 Control Applet |
Signatech Controller Software
Signatech software enables the user to program all strobe controller current and timing parameters. Currents are programmable for each of four channels per output, and expressed in milliamps from 0-4000. Timing parameters include pulse width, pre and post event delay time, trigger repeat setting, and a programmable off time between repetitions. All timing parameters are programmed in steps of 1 microsecond, up to a maximum of 64000.
Upon detection of unsafe operating parameters, Signatech will retard either current or timing (selectable) ensuring continuous reliable operation. the software allows three modes of operation: Continuous (DC), Trigger (strobe), and Test. All output settings can be saved and recalled later. Settings already programmed into a Signatech strobe controller can be queried from the controller and saved to a file. The last used settings are recalled automatically at startup. |
| |
Additional Information |
Pulse Parameter |
Range |
Computer Increment |
On Time |
0 or 1 to 64000 |
1 microsec |
Delay Time |
0 or 10 to 64000 |
1 microsec |
Stop Time |
0 or 1 to 64000 |
1 microsec |
Off Time |
0 or 1 to 64000 |
1 microsec |
Hold Time |
0 or 50 to 64000 |
1 microsec | |
Standard Product Information |
Operating Temperature: |
0-55°C |
Regulatory Compliance |
CE | |
S6000 Schematic |
| |
DIMENSIONS ARE IN MILLIMETERS (INCHES) | |