|
Pulsar 320 |
Download Sales Sheet |
- Compact, high power pulse (STROBE ONLY) current source
- Controlled locally w/PC and USB2, or remotely w/built-in Ethernet interface
- 50A per output; 100A total output
| |
Click to Expand for Specifications |
Pulsar 320 Control Applet |
Signatech software enables the user to program all strobe controller current and timing parameters. Currents are programmable for each of 2 outputs, and expressed in amps from 0-50. Timing parameters include pulse width, and post event delay time. All timing parameters are programmed in steps of 1 microsecond, up to a maximum of 100,000. |
| |
Additional Information |
Pulse Parameter |
Range |
Computer Increment |
On Time |
|
|
Delay Time |
|
|
Stop Time |
|
|
Off Time |
|
|
Hold Time |
|
| |
Standard Product Information |
Operating Temperature: |
0 - 55°C |
Regulatory Compliance |
CE | |
Pulsar 320 Schematic |
| |
DIMENSIONS ARE IN MILLIMETERS (INCHES) | |
|
Pulsar 710 |
Download Sales Sheet |
- 100 Amps @ 100 Volts total output in strobed mode
- 8 Amps @ 24 Volts total output in constant mode
- Capable of strobing Ai's largest lights
| |
Click to Expand for Specifications |
Pulsar 710 Control Applet |
Signatech software enables the user to program all strobe controller current and timing parameters. Currents are programmable for each of four channels, and expressed in amps from 0-25. Timing parameters include pulse width, and post event delay time. All timing parameters are programmed in steps of 1 microsecond, up to a maximum of 1000. |
| |
Additional Information |
Pulse Parameter |
Range |
Computer Increment |
On Time |
|
|
Delay Time |
|
|
Stop Time |
|
|
Off Time |
|
|
Hold Time |
|
| |
Standard Product Information |
Operating Temperature: |
0-55°C |
Regulatory Compliance |
CE | |
Pulsar 710 Schematic |
| |
DIMENSIONS ARE IN MILLIMETERS (INCHES) | |
|
S4000 |
Download Sales Sheet |
- Features Ai’s proprietary Signatech system
- Provides up to 4 Amps per channel, 4 channels per output
- THE S4000 WILL BE DISCONTINUED JULY 1, 2010, REPLACED BY THE Pulsar 320 OR iSU
| |
Click to Expand for Specifications |
S4000 Control Applet |
Signatech Controller Software
Signatech software enables the user to program all strobe controller current and timing parameters. Currents are programmable for each of four channels per output, and expressed in milliamps from 0-4000. Timing parameters include pulse width, pre and post event delay time, trigger repeat setting, and a programmable off-time between repetitions. All timing parameters are programmed in steps of 1 microsecond, up to a maximum of 64000. |
| |
Additional Information |
Pulse Parameter |
Range |
Computer Increment |
On Time |
0 or 1 to 64000 |
1 microsec |
Delay Time |
0 or 10 to 64000 |
1 microsec |
Stop Time |
0 or 1 to 64000 |
1 microsec |
Off Time |
0 or 1 to 64000 |
1 microsec |
Hold Time |
0 or 50 to 64000 |
1 microsec | |
Standard Product Information |
Operating Temperature: |
0-55°C |
Regulatory Compliance |
CE | |
S4000 Schematic |
| |
DIMENSIONS ARE IN MILLIMETERS (INCHES) | |
|
S6000 |
Download Sales Sheet |
- Two independently controlled light head outputs are provided, allowing two cameras to be used in a dual inspection configuration
- Up to 4 Amps per channel, 4 channels per output
- THE S6000/S6000-AS WILL BE DISCONTINUED JULY 1, 2010, REPLACED BY THE Pulsar 320 OR iSU
| |
Click to Expand for Specifications |
S6000 Control Applet |
Signatech Controller Software
Signatech software enables the user to program all strobe controller current and timing parameters. Currents are programmable for each of four channels per output, and expressed in milliamps from 0-4000. Timing parameters include pulse width, pre and post event delay time, trigger repeat setting, and a programmable off time between repetitions. All timing parameters are programmed in steps of 1 microsecond, up to a maximum of 64000.
Upon detection of unsafe operating parameters, Signatech will retard either current or timing (selectable) ensuring continuous reliable operation. the software allows three modes of operation: Continuous (DC), Trigger (strobe), and Test. All output settings can be saved and recalled later. Settings already programmed into a Signatech strobe controller can be queried from the controller and saved to a file. The last used settings are recalled automatically at startup. |
| |
Additional Information |
Pulse Parameter |
Range |
Computer Increment |
On Time |
0 or 1 to 64000 |
1 microsec |
Delay Time |
0 or 10 to 64000 |
1 microsec |
Stop Time |
0 or 1 to 64000 |
1 microsec |
Off Time |
0 or 1 to 64000 |
1 microsec |
Hold Time |
0 or 50 to 64000 |
1 microsec | |
Standard Product Information |
Operating Temperature: |
0-55°C |
Regulatory Compliance |
CE | |
S6000 Schematic |
| |
DIMENSIONS ARE IN MILLIMETERS (INCHES) | |
|
iSU |
Download Sales Sheet |
- Built into the power cable
- Manual potentiometer adjustable range of 30 to 300µSec output pulse-width
- Timing bypass option
| |
Click to Expand for Specifications |
iSU Control Applet |
The ISU is a small, lightweight strobe source designed to drive LED light assemblies up to a maximum current of 12A (pulse-width dependent). The unit resides outside of the associated light head being placed “inline” with the light head power cable. Maximum light head drive current is set at the factory for a given light source while a user adjustable range of 30 to 300µSec output pulse width is available (via potentiometer or through trigger pulse width).
The unit has two triggering modes of operation:
Fixed Trigger Mode: Selectable pulse width range of 30-300µSeconds that is accessible via user-adjust potentiometer.
Timing Bypass Trigger Mode: Output Pulse width follows the width of input trigger. User-adjust potentiometer sets the maximum.
|
| |
Additional Information |
Pulse Parameter |
Range |
Computer Increment |
On Time |
|
|
Delay Time |
|
|
Stop Time |
|
|
Off Time |
|
|
Hold Time |
|
| |
Standard Product Information |
Operating Temperature: |
°C |
Regulatory Compliance |
CE | |
iSU Schematic |
| |
DIMENSIONS ARE IN MILLIMETERS (INCHES) | |